Mitsubishi Motors DS5000TK User Manual

Page 34

Advertising
background image

USER’S GUIDE

050396 33/173

34

TCON.0:

IT0

“Interrupt 0 Type Select”:

When set to 1, 1–to–0 transitions on INT0 will be used to generate interrupt
requests from this pin. When cleared to 0, INT0 is level–activated.

Initialization:

Cleared to a 0 on any type of reset.

TIMER MODE REGISTER

Label: TMOD

Register Address: 089H

D7

D6

D5

D4

D3

D2

D1

D0

GATE

C/T

M1

M0

GATE

C/T

M1

M0

Bit Description:

TMOD.7 (Timer 1);
TMOD.3 (Timer 0):

GATE

“Gate Control”:

When set to 1 with TRn=1, timer/counter’s input count pulses will only be
delivered while a 1 is present on the INT pin. When cleared to 0, count
pulses will always be received by the timer/counter a long as TRn=1.

Initialization:

Cleared to 0 on any reset.

TMOD.6 (Timer 1);
TMOD.2 (Timer 0)

C/T

“Counter/Timer Select”:

When set to 1, the counter function is selected for the associated timer;
when cleared to 0, the timer function is selected.

Initialization:

Cleared to 0 on any reset.

TMOD.5, TMOD.4 (Timer 1);
TMOD.1, TMOD.0 (Timer 0): M1,M0

“Mode Select”:

These bits select the operating mode of the associated timer/counter as fol-
lows:

M1

M0

0

0

Mode 0: 8 bits with 5–bit prescale

0

1

Mode 1: 16 bits with no prescale

1

0

Mode 2: 8 bits with auto–reload

1

1

Mode 3: Timer 0 – Two 8–bit timers
Timer 1 – Stopped

Initialization:

Cleared to 0 on any reset.

Advertising