Instructions for Installation (cont’d)

10. Carefully disconnect wiring harness terminal connector

from back of thermostat.

11. Remove the wall plate from the water heater by unscrewing

the two mounting screws. The wall plate will be installed at
the selected location in Steps 28 and 29.

12. Loosen each screw in the terminal connector and remove the

wire ends. The terminal connector will be installed at the
selected remote location in Step 31.

13. Press the end of the thermostat cable back into the insulating

bushing. No other connections will be made to this end of
the cable.

14. Close and latch outer door.

REMOTE THERMOSTAT WIRING AT WATER HEATER

15. Remove mounting screw and right junction box cover. Also

lift up and remove black plug on left junction box cover.
Discard plug.

BACK OF

THERMOSTAT

TERMINAL

CONNECTOR

THERMOSTAT

CABLE

MOUNTING

SCREWS

WALL PLATE

TERMINAL

CONNECTOR

WIRING

HARNESS

SCREW

SLOTS

WIRING

HARNESS

INSULATING

BUSHING

BLACK

PLUG

RIGHT JUNCTION

BOX COVER

LEFT JUNCTION

BOX COVER