Selecting Thermostat Location (cont’d)

20

22. Guide the end of the remote thermostat cable through the

hole where the black plug was removed in the left junction
box cover.

24. Loosen each screw in the terminal connector one at a time

and insert wire with the same color insulation into each
numbered slot
. Tighten each screw securely making sure
both wires in each slot are tight.

23. Strip the end of the remote thermostat cable outer insulation

back 1

1

4

inches. Strip the ends

1

4

inch on each of the six col-

ored wires.

25. Carefully press the terminal connector and connected wires

down into the water heater junction box.

26. A strain-relief bushing is also provided in the small bag that

contained the terminal connector. Open the bushing and
place it around the remote thermostat cable exiting the junc-
tion box. Press the bushing into the hole in the left junction
box cover.

27. Replace the right junction box cover using the screw provid-

ed. This completes the remote thermostat wiring at the water
heater.

REMOTE THERMOSTAT INSTALLATION AND WIRING

28. Locate the 6 inches of remote thermostat cable protruding

through the wall opening (from Step 8). Using the wall plate
removed in Step 11, pull the cable through opening near cen-
ter of wall plate.

Instructions for Installation (cont’d)

REMOTE

THERMOSTAT

CABLE

LEFT JUNCTION

BOX COVER

TERMINAL

CONNECTOR

THERMOSTAT

CABLE FROM

WATER HEATER

REMOTE

THERMOSTAT

CABLE

WALL

PLATE

WALL

OPENING

REMOTE

THERMOSTAT

CABLE

REMOTE

THERMOSTAT

CABLE

TERMINAL

CONNECTOR

INSULATING

STRAIN-RELIEF

BUSHING

ORANGE/WHITE

ORANGE

GREEN/WHITE

GREEN

BLUE/WHITE

BLUE

.250