7-2.

Diagnostics (Continued)

ERR TEMP

•

The temperature error indicates welding

power source has overheated and

shutdown. The error may be cleared by

allowing unit to cool down, and pressing the

Jog/Purge button.

ERR LINE

•

The line error indicates input power is

outside of unit operating range. Check and

correct input power. Press Jog/Purge

button to clear error.

ERR ARC

•

The arc error indicates an arc outage

occurred possibly from a wire feeder error

or power source error. Check wire feeder

and power source. Press Jog/Purge button

to clear error.

ERR POL

•

The polarity error indicates the polarity is

different than the selected polarity. Check

and correct weld cable connections. Press

Jog/Purge button to clear error.

UNIT MEM

•

The unit memory error indicates the PCM

board lost memory data. Press Jog/Purge

button to clear error.

UIM MEM

•

The uim memory error indicates user

interface board lost memory data. Press

Jog/Purge button to clear error.

MOTR MEM

•

The motor memory error indicates motor

board lost memory data. Press Jog/Purge

button to clear error.

WELD WAIT

•

The weld wait error indicates unit was not

ready for a weld sequence. Press Jog/

Purge button to clear error.

MOTR COM

•

The motor communication error indi-

cates motor board lost data communica-

tions. Press Jog/Purge button to clear error.

PLS WAIT

•

The uim communication error indicates

user interface board lost data

communications. Press Jog/Purge button

to clear error.

OVER CRNT

•

The over current error indicates welding

power source primary current is too high.

Check and correct input power. Press Jog/

Purge button to clear error.

LOW WFS

•

The low wire feed speed error indicates

actual wire feed speed is lower than wire

feed speed command. Check for

obstructions in the wire feed system or a

faulty wire drive system. Press Jog/Purge

button to clear error.

UNIT

MEM

UIM

MEM

MOTR

MEM

WELD

WAIT

MOTR

COM

PLS

WAIT

Indicates a memory

CRC PCM error.

Indicates a memory

CRC UIM error.

Indicates a memory

CRC motor error.

Indicates a weld

cycle wait error.

Indicates a motor

communication error.

Indicates a UIM

communication error.

OVER

CRNT

LOW

WFS

Indicates an

overcurrent error.

Indicates a low WFS

command error.

ERR

TEMP

ERR

LINE

ERR

ARC

ERR

POL

Indicates a

temperature error.

Indicates a line

error.

Indicates an arc

error.

Indicates a polarity

error.