Over crnt low wfs, Err temp err line err arc err pol, 2 . diagnostics (continued) – Miller Electric 75 User Manual
Page 34
OM-228 956 Page 30
7-2.
Diagnostics (Continued)
ERR TEMP
•
The temperature error indicates welding
power source has overheated and
shutdown. The error may be cleared by
allowing unit to cool down, and pressing the
Jog/Purge button.
ERR LINE
•
The line error indicates input power is
outside of unit operating range. Check and
correct input power. Press Jog/Purge
button to clear error.
ERR ARC
•
The arc error indicates an arc outage
occurred possibly from a wire feeder error
or power source error. Check wire feeder
and power source. Press Jog/Purge button
to clear error.
ERR POL
•
The polarity error indicates the polarity is
different than the selected polarity. Check
and correct weld cable connections. Press
Jog/Purge button to clear error.
UNIT MEM
•
The unit memory error indicates the PCM
board lost memory data. Press Jog/Purge
button to clear error.
UIM MEM
•
The uim memory error indicates user
interface board lost memory data. Press
Jog/Purge button to clear error.
MOTR MEM
•
The motor memory error indicates motor
board lost memory data. Press Jog/Purge
button to clear error.
WELD WAIT
•
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
•
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
PLS WAIT
•
The uim communication error indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error.
OVER CRNT
•
The over current error indicates welding
power source primary current is too high.
Check and correct input power. Press Jog/
Purge button to clear error.
LOW WFS
•
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
UNIT
MEM
UIM
MEM
MOTR
MEM
WELD
WAIT
MOTR
COM
PLS
WAIT
Indicates a memory
CRC PCM error.
Indicates a memory
CRC UIM error.
Indicates a memory
CRC motor error.
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
OVER
CRNT
LOW
WFS
Indicates an
overcurrent error.
Indicates a low WFS
command error.
ERR
TEMP
ERR
LINE
ERR
ARC
ERR
POL
Indicates a
temperature error.
Indicates a line
error.
Indicates an arc
error.
Indicates a polarity
error.