4-6. Remote 14 Receptacle Information

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

A

J

B

K

I

24 VOLTS AC

B

Contact closure to A completes 24 volts ac con-

tactor control circuit.

B

I

C L N

H

115 VOLTS AC

I

115 volts ac. Protected by circuit breaker CB1.

C

D M

G

E

F

115 VOLTS AC

J

Contact closure to I completes 115 volts ac con-

tactor control circuit.

REMOTE

C

Output to remote control; 0 to +10 volts dc, +10

volts dc in MIG mode.

REMOTE

OUTPUT

CONTROL

D

Remote control circuit common.

CONTROL

E

0 to +10 volts dc input command signal from re-

mote control.

A/V

H

Voltage feedback; +1 volt dc per 10 output recep-

tacle volts.

A/V

AMPERAGE

VOLTAGE

F

Current feedback; +1 volt dc per 100 amperes.

ST-801 192

VOLTAGE

M

CC/CV select

GND

G

Circuit common for 24 and 115 volts ac circuits.

GND

K

Chassis common.

*The remaining sockets are not used.

4-7. 110 Volt AC Duplex Receptacle

Ref. ST-801 245-A

1

110 V 7 A AC Receptacle

Power is shared between duplex

receptacle and Remote 14 recep-

tacle (see Section 4-6).
2

Circuit Breaker CB1

3

Circuit Breaker CB2

CB1 protects 110 volt ac portion of

duplex receptacle and Remote 14

receptacle from overload.
CB2 protects 24 volt ac portion of

Remote 14 receptacle from

overload.
Press button to reset breaker.

2

3

1

Advertising