EM316E1 Jumper Settings for E1 120

Application :


1)

Install jumpers between JP3 pins 1 and 2,


2)

No jumpers on JP4 and JP5 open, (all pins are open)

3)

Set all switches on S1 to ON.

(BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing
mode










2 4

1 3

JP3

1

1

JP4

JP5

1

2

3

4

5

O

N

S1

LINE LENGTH BIT0

LINE LENGTH BIT1

LINE LENGTH BIT2

RECEIVE CODE TYPE

TRANSMIT CODE TYPE