Application – MRV Communications EM316E1 User Manual

Page 12

Advertising
background image

Fiber Driver

EM316E1/EM316T1


P/N: 1218003-001, REV_O PAGE 12

EM316E1 Jumper Settings for E1 75

Application :

1)

Install jumpers between JP3 pins 3 and 4,



2)

Install jumpers between JP4 pins 1 and 2, JP5 pins 1 and 2



3)

Set all switches on S1 to ON.

(BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing
mode






2 4

1 3

JP3

2

JP4

JP5

2

1

1

1

2

3

4

5

O

N

S1

LINE LENGTH BIT0

LINE LENGTH BIT1

LINE LENGTH BIT2

RECEIVE CODE TYPE

TRANSMIT CODE TYPE

Advertising
This manual is related to the following products: