Miller Electric 652 User Manual

Page 29

Advertising
background image

OM-228 470 Page 25

4-13. Remote 14 Receptacle RC8 And Terminal Strip 1T Information

Socket

Terminal

Information

24 VOLTS AC

A

A

24 volts ac. Protected by supplementary protector CB2.

24 VOLTS AC

B

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

C

Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).

REMOTE OUTPUT CONTROL

D

D

Remote control circuit common.

E

E

0 to +10 volts dc input command signal from remote control.

F

*

Current feedback; 1 volt per 100 amperes.

H

*

Voltage feedback; 1 volt per 10 arc volts.

115 VOLTS AC

I

I

115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector

CB1.

115 VOLTS AC

J

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

K

*

Chassis common.
Circuit common for 24 and 115 volts ac circuits.

REMOTE POWER ON/OFF

*

L

To remote On/Off switch

REMOTE POWER ON/OFF

*

M

To remote On/Off switch.

REMOTE VOLTAGE SENSING

N

N

Voltage sensing signal from Negative (−) weld output terminal.

REMOTE VOLTAGE SENSING

*

P

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used