Marantz PD6120D User Manual

Page 53

Advertising
background image

46

22. Audio Select Set

Function
The external control equipment sets combinations of audio and video inputs
for the plasma monitor.
Transmission Data

DFH

80H

60H

70H

02H

DATA00 DATA01 CKS

DATA00: AUDIO INPUT

01H:

AUDIO 1

02H:

AUDIO 2

03H:

AUDIO 3

DATA01: VISUAL INPUT

01H:

Video 1

02H:

Video 2

03H:

Video 3

05H:

HD (HD1 or DTV or DTV1)

06H:

HD2 (DTV2)

07H:

RGB 1/ PC 1

08H:

RGB 2/ PC 2

0CH:

RGB 3/ PC 3

ACK
The plasma monitor returns the following ACK when the input is switched.

3FH

60H

80H

70H

00H

CKS

* The plasma monitor returns “Not Available” when selecting the
video input same as the one set at one of the AUDIO 01 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the
VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to
AUDIO1.

23. Audio Select Request

Function
The external control equipment inquires the current combinations of audio
and video inputs for the plasma monitor.
Transmission Data

1FH

80H

60H

6FH

00H

CKS

ACK
The plasma monitor returns the following ACK:

7FH

60H

80H

6FH

03H

DATA00 DATA01 DATA02 CKS

DATA00: AUDIO 1

01H - 0CH: VISUAL INPUT DATA

DATA01: AUDIO 2

01H - 0CH: VISUAL INPUT DATA

DATA02: AUDIO 3

01H - 0CH: VISUAL INPUT DATA
VISUAL INPUT DATA
01H:

Video 1

02H:

Video 2

03H:

Video 3

05H:

HD (HD1 or DTV or DTV 1)

06H:

HD2 (DTV2)

07H:

RGB 1 /PC 1

08H:

RGB 2 /PC 2

0CH:

RGB 3 /PC 3

24. LONG LIFE Set

Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse
of image brightness) of the plasma monitor.

Transmission Data

DFH

80H

60H

6BH

03H

DATA00 DATA01 DATA02 CKS

DATA00 : PLE

01H:

AUTO

02H:

LOCK

DATA01 : INVERSE

01H:

ON

02H:

OFF

03H:

WHITE

DATA02 : ORBITER (PICTURE SHIFT)

01H:

ON

02H:

OFF

ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER,
and INVERSE (inverse of image brightness):

3FH

60H

80H

6BH

00H

CKS

25. Failure Mode Request

Function
The external control equipment inquires the detection of failures of the plasma
monitor.

Transmission Data

1FH

80H

60H

3FH

00H

CKS

ACK
The plasma monitor returns the following ACK:

7FH

60H

80H

3FH

02H

DATA00 DATA01 CKS

DATA00: FAILURE MODE 1

Bit 0 :

PDP MODULE
0: Abnormal
1: Normal

Bit 1 :

1: fixed (backup)

Bit 2 :

TEMPERATURE
0: Abnormal
1: Normal

Bit 3 :

FAN
0: Abnormal
1: Normal

Bit 4 :

1: fixed (backup)

Bit 5 :

1: fixed (backup)

Bit 6 :

1: fixed (backup)

Bit 7 :

1: fixed (backup)

DATA01:FILURE MODE 2

Bit 0–7 : 1: fixed (backup)

Advertising