Please read the ”Warning and
Safety Instructions“ to avoid the
danger of toxic fumes.

The DA-8 extractor should be in-
stalled in accordance with local and
national building regulations.

The exhaust connection should be
made into a vent shaft or chimney that
is not in use, using non-flammable ex-
haust ducting to the outside by using a
wall vent kit. These kits are available
from the Miele Parts Department.

Installation should only be per-
formed out by a suitably qualified
and trained person.

The exhaust ducting should be as
short and straight as possible.

The use of angled pipes should be
avoided, as this will reduce the air
flow of the extractor.

Only use ducting made of non-
flammable material.

The exhaust ducting may be angled
either to the left, right or downwards.

If the ducting is run beneath the
cabinets it requires a toe kick height
of at least 5-15/16 ’’.

If the ducting is run horizontally, en-
sure that there is a gradient of at
least 1/8 ’’ per foot, so that condensa-
tion will not run into the appliance.