4-2.
Motorized Slide Limit Switch
Ref. ST-154 578
1
Limit Switch
2
Slide Stop
3
Nut
Slide movement stops when stop
hits limit switch.
This can be used as a starting refer-
ence point for weld repeatability.
The stop can be adjusted. Loosen
nut, turn screw in or out to desired
length, and tighten nut.
Tools Needed:
7/16 in.
1
2
3
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1.
Routine Maintenance
Every month, check labels and cables; clean all parts. Yearly clean and oil slide, and clean and adjust drive belt.
5-2.
Overload Protection
ST-154 638 / Ref. ST-151 186
Turn OFF and unplug unit.
If fuse F1 opens, the slide and con-
trol do not work. To check or change
F1, proceed as follows:
1
Fuse Holder Cover
Press and turn cover counterclock-
wise. Pull out fuse with cover.
2
Fuse F1 (See Parts List For
Rating)
Insert new fuse into cover, and in-
stall fuse with cover by pressing
and turning cover clockwise.
1