background image

OM-1096 Page 10

4-2.

Motorized Slide Limit Switch

Ref. ST-154 578

1

Limit Switch

2

Slide Stop

3

Nut

Slide movement stops when stop
hits limit switch.

This can be used as a starting refer-
ence point for weld repeatability.

The stop can be adjusted. Loosen
nut, turn screw in or out to desired
length, and tighten nut.

Tools Needed:

7/16 in.

1

2

3

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

5-1.

Routine Maintenance

Every month, check labels and cables; clean all parts. Yearly clean and oil slide, and clean and adjust drive belt.

5-2.

Overload Protection

ST-154 638 / Ref. ST-151 186

Turn OFF and unplug unit.

If fuse F1 opens, the slide and con-
trol do not work. To check or change
F1, proceed as follows:

1

Fuse Holder Cover

Press and turn cover counterclock-
wise. Pull out fuse with cover.

2

Fuse F1 (See Parts List For
Rating)

Insert new fuse into cover, and in-
stall fuse with cover by pressing
and turning cover clockwise.