Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments IS3480-00 User Manual

Page 43

Advertising
background image

39

S

CANNER

AND

C

ABLE

T

ERMINATIONS

Scanner Pinout Connections

IS3480-102 RS232, TTL

Pin

Function

1

Ground

2

Transmit (Full RS232)

3

Receive (Full RS232)

4

RTS Output (TTL RS232)

5

CTS Input (TTL RS232)

6

DTR Input (TTL RS232)

7

Transmit (TTL RS232)

8

Receive (TTL RS232)

9

+5VDC

The IS3480 scanner interfaces terminate
to a 10-pin modular socket. The serial #
label indicates the interface enabled when
the scanner is shipped from the factory.

Figure 15.

10

Shield Ground

IS3480-47 Keyboard Wedge

and Stand-Alone Keyboard

IS3480-41

RS232C and Light Pen Emulation

Pin

Function

Pin

Function

1

Ground

1

Ground

2

RS232 Transmit Output

2

RS232 Transmit Output

3

RS232 Receive Input

3

RS232 Receive Input

4

PC Data

4

RTS Output

5

PC Clock

5

CTS Input

6

KB Clock

6

DTR Input/LTPN Source

7

PC +5V

7

Reserved

8

KB Data

8

LTPN Data

9

+5VDC

9

+5VDC

10

Shield Ground

10

Shield Ground

IS3480-40 Full Speed USB

RS232 Low Speed USB,

HID IS3480-38 and POS IS3480-39

Pin

Function

Pin

Function

1

Ground

1

Ground

2

RS232 Transmit Output

2

No Connect

3

RS232 Receive Input

3

No Connect

4

RTS

4

No Connect

5

CTS

5

No Connect

6

USB D+

6

D+

7

V USB

7

PC +5V/V_USB

8

USB D-

8

D-

9

+5VDC

9

No Connect

10

Shield Ground

10

Drain Wire

Continued on next page.

Advertising