MODEL RATING PLATE

FLOOR DRAIN

DISCHARGE PIPE

(Do not cap or

plug)

6” AIR GAP

HOT

15

COLD

TEMPERATURE-

PRESSURE

RELIEF VALVE

CONDUIT

HOT

COLD

Installation Checklist

1. Whether or not the element conversion is made, the

model rating plate must be marked. Using a hard
point ink pen, check the appropriate block within the
model rating plate, which is located adjacent to the
lower access panel.

2. Is the fuse or circuit breaker size correct as shown in

the chart in the “Product Specifications” section?

3. Are the wires from the circuit breaker or fuse service to

the water heater’s junction box on the correct wire size
(gauge) as shown in the chart in the “Product
Specifications” section?

4. Is the new temperature-pressure relief valve properly

installed, and piped to an adequate drain? See
“Temperature-Pressure Relief Valve” in the
“Instructions for Installation” section.

5. Is the water heater completely filled with water? See

“Filling the Water Heater” instructions in the
“Instructions for Installation” section.

6. Will a water leak damage anything? See “Locating

the New Water Heater” in the “Instructions for
Installation” section.

7. Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the
“Instructions for Installation” section.

8. Is there adequate clearance for maintenance around

the water heater?

9. Do you need to call your electric company to check

your wiring?

Instructions for Installation (cont’d)

Advertising