Service and maintenance (cont’d), Element cleaning/ replacement, Thermostat removal (cont’d) – Maytag ELECTRIC WATER HEATER HR630DJLS User Manual

Page 19

Advertising
background image

19

Service and Maintenance (cont’d)

5. Remove the block of insulation and pad to expose

the terminal cover.

3. Attach a hose to the water heater drain valve and put

the other end in a floor drain or outdoors. Open the
water heater drain valve. Open a nearby hot water
faucet which will relieve pressure in the water heater
and speed draining.

4. Remove the two screws securing the access panel,

and remove panel.

WARNING

The water passing out of the drain valve may be
extremely hot. To avoid being scalded, make sure all
connections are tight and that the water flow is directed
away from any person.

2. Turn off the water supply to the water heater at the

water shutoff valve or water meter.

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any
access panels or servicing the water heater, make sure
the electrical supply to the water heater is turned “OFF”.
Failure to do this could result in DEATH, SERIOUS
BODILY INJURY, OR PROPERTY DAMAGE.

NOTE: These instructions are written for element
cleaning and element replacement for the lower
element. If it is necessary to clean or replace the
upper element, then repeat these instructions.

To remove the element from your tank in order to clean
or replace it:

1. Before beginning turn “OFF” the electric power supply

to the water heater.

Element Cleaning/
Replacement

9. Put plastic terminal cover back in place.

10.Replace the insulation block and pad to cover the

thermostat.

11. Replace access panel, then turn the electric power “ON”.

Thermostat Removal (cont’d)

Advertising