3.4.6 Operations and Maintenance Commands

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Upgrade Slot

USI=

1 bytes, value
of 0,1 or 2

Command or Query.
Slot to upgrade new IP firmware where,

0= Oldest
1=Image 1
2=Image 2

Example: UPS=0

USI =
USI!

USI?

USI=x
(see description of
arguments)

Software
Revision

N/A

34-37 bytes

Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form :
Example:
>0001/SWR=Boot:1.1.1 Bulk1:1.5.1u Bulk2:1.5.1P

SWR!

SWR?

SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(see description
of arguments)

Advertising