2-9. Inductance Selection (300 Ampere Models)

Y Disconnect and lockout/tag-

out input power before re-

moving side panel.

Lockout/tagging procedures con-

sist of padlocking line disconnect

switch in open position, removing

fuses from fuse box, or shutting off

and red-tagging circuit breaker or

other disconnecting device.
1

Stabilizer Z

Tapped stabilizer Z is factory

connected to the stabilizer tap

which suits most GMAW

applications.
Stabilizer Z controls the inductance

applied to the weld current. To in-

crease inductance and wet out the

weld puddle, connect to stabilizer Z

ending.
To change inductance proceed as

follows:
2

Lead 25

3

Stabilizer Z Tap

4

Stabilizer Z Ending

5

Lead 26

To increase inductance, connect

lead 26 to stabilizer ending and

secure.
Reinstall side panel.
6

Typical Weld Bead Using The

Tap Stabilizer Connection

Use the tap Stabilizer connection to

obtain arc type and weld bead suit-

able for some mild steel applica-

tions.
7

Typical Weld Bead Using The

End High Stabilizer

Connection

Use the end Stabilizer connection

to reduce weld bead crowning, and

spread the weld puddle.

ST-801 379-B

3/8, 7/16 in

3/8 in

1

2

3

4

5

6

7

Weld Bead Using The Tap Stabilizer

Connection With 17 Volts, 100 Amps

Weld Bead Using The End Stabilizer

Connection With 17 Volts, 100 Amps