28

TROUBLESHOOTING

12

The transceiver does
not turn ON.
No sound from the
speaker.

Transmitting is impos-
sible, or high power
can not be selected.

The displayed channel
cannot be changed.
Scan does not start.
No beeps.

Self check error.
(Temperature)

Self check error.
(Battery voltage)
Transmitting continu-
ously while not speak-
ing when using VOX
function.

• The battery is exhausted.
• Bad connection to the battery pack.
• Squelch level is too deep.
• Volume level is too low.
• Speaker has been exposed to water.
• Water has entered to [SP MIC] connector.
• Some channels are for low power or re-

ceive only.

• The battery is exhausted.
• The battery is over charged.
• The output power is set to low.
• Lock function is activated.

• “TAG” channels are not programmed.
• Beep tones are turned OFF.

• The temperature is outside of –35°C to

+73°C; –31°F to +163°F (approx)

• The connected battery pack’s voltage is

more than 11 V.

• Ambient noise is too loud.

• Recharge the battery pack.
• Check the connection to the transceiver.
• Set squelch to the threshold point.
• Rotate [VOL] to set a suitable level.
• Drain water from the speaker.
• Dry [SP MIC] connector.
• Change channels.

• Recharge the battery pack.
• Verify the battery voltage is correct.
• Push [Hi/Lo•

] to select high power.

• Push [Hi/Lo•

] for 1 sec. to cancel the

function.

• Set the desired channels as “TAG” channels.
• Set the beep tones to ON (Fix Beep/User

Beep) on the SET mode.

• Leave the transceiver at room temperature

for a while. Turn the power ON to check if the
internal temperature has returned to normal.

• Verify the battery voltage is correct.

• Remove the headset cable.
• Set the VOX gain to dulling.

p. 22

p. 3
p. 9
p. 9


pgs. 8,

9, 29
p. 23

p. 9

p. 10

p. 13
p. 17

p. 21

PROBLEM

POSSIBLE CAUSE

SOLUTION

REF.

Advertising