Adjustment procedures, Preparation, 1 preparation – Icom IC-M802 User Manual
Page 18

4 - 1
4-1 PREPARATION
When adjusting the contents on page 4-9, a JIG CABLE (see illustration as shown below) is required.
Some adjustments must be performed on the “ADJUSTMENT MODE”. Entering the “ADJUSTMENT MODE”, see the next page.
■ REQUIRED TEST EQUIPMENT
SECTION 4 ADJUSTMENT PROCEDURES
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
Digital multimeter
GRADE AND RANGE
Output voltage
: 13.6 V DC
Current capacity
: 30 A or more
Measuring range
: 1–100 W
Frequency range
: 0.5–30 MHz
Impedance
: 50
Ω
SWR
: Less than 1.2 : 1
Frequency range
: 0.1–600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity
: 100 mV or better
Frequency range
: DC–600 MHz
Measuring range
: 0 to ±5 kHz
Input impedance
: 10 M
Ω/V DC or better
EQUIPMENT
Audio generator
Attenuator
Standard signal
generator (SSG)
DC voltmeter
Oscilloscope
AC millivoltmeter
GRADE AND RANGE
Frequency range
: 300–3000 Hz
Output level
: 1–500 mV
Power attenuation
: 40 or 50 dB
Capacity
: 100 W or more
Frequency range
: 0.5–30 MHz
Output level
: 0.1 µV–32 mV
(–127 to –17 dBm)
Input impedance
: 50 k
Ω/V DC or better
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
Measuring range
: 10 mV–10 V
to [SP]
to [CONTROLLER]
[MIC] connector
to antenna connector 1/2
to antenna connector 1
Speaker
6
5
4
2
3
8
7
1
Modulation analyzer
Distortion meter
Standard signal
generator
CAUTION!
DO NOT transmit while
an SSG is connected to
the antenna connector 1.
DC power supply
Ammeter
Attenuator
Spectrum scope
+
_
RF power meter
• CONNECTION