4-4 RECEIVER ADJUSTMENTS

”TOTAL GAIN”, “S-METER” and “DSC PEAK” adjustments must be performed at “ADJUSTMENT MODE”.

NOISE NULL
POINT

RECEIVER
GAIN

TOTAL GAIN

S-METER

DSC PEAK
([USA],[CAN]
only)

DSC SELF
CHECK
([USA],[CAN]
only)

1

1

1

1

2

1

1

• Operating frequency : 0.5 MHz
• Mode

: H3E

• Preset L402 and L405 to max. clock-

wise.

• Preset L401, L403, L404 and L801 to

max. counter clockwise.

• Set the standard signal generator to

OFF (no signal output).

• Receiving

• Operating frequency : 12.2310 MHz
• Mode

: J3E

• Connect a standard signal generator

to the [ANT] connector and set as:

Frequency

: 12.2310 MHz

Level

: 0.5 µV*

(–113 dBm)

Modulation

: OFF

• Receiving

• While pushing HM-135’s “DOWN” key,

[TX] and [RX] switches, then turn
power ON.

• Push [2] swtich to enter the RX adjust-

ment mode.

• Connect a standard signal generator

to the [ANT] connector and set as:

Frequency

: 12.3540 MHz

Level

: 320 µV*

(–57 dBm)

Modulation

: OFF

• Receiving

• Set the standard signal generator to

OFF (no signal output).

• Set the standard signal generator as:

Frequency

: 12.3540 MHz

Level

: 10 mV*

(–27 dBm)

• Receiving

• Push [3] switch to enter the DSC

adjustment mode.
LCD displayed :“DSC ADJUSTMENT”.

• DSC frequency

: 8.4145 MHz

• Connect a standard signal generator

to the [DSC ANT] connector and set
as:

Frequency

: 8.4145 MHz

Level

: 0.5 µV*

(–113 dBm)

Modulation

: OFF

• Receiving

• LCD displayed :”DSC SELF CHECK”
• DSC frequency

: 8.4145 MHz

• Connect an RF power meter to the

[DSC ANT] connector on the rear
panel.

• Receiving

Front

panel

Front

panel

Front

panel

Connect an AC milli-
voltmeter to the [SP]
jack with a 4

Ω dummy

load.

Connect an AC milli-
voltmeter to the [SP]
jack with a 4

Ω dummy

load.

Connect an AC milli-
voltmeter to the [SP]
jack with a 4

Ω dummy

load.

Minimum output

level

Maximum out-

put level

Maximum out-

put level

MAIN

MAIN

MAIN

L207

L208,
L209,
L210,
L301,
L302,

L307

L2306,

L2307

ADJUSTMENT

ADJUSTMENT CONDITIONS

UNIT

LOCATION

VALUE

UNIT

ADJUST

MEASUREMENT

ADJUSTMENT

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

• Push the [ENT] switch to write the adjustment value in the mem-

ory.

• Push the [ENT] switch to write the adjustment value in the mem-

ory.

• Push the [ENT] switch to write the adjustment value in the mem-

ory.

4 - 7

• Push the [ENT] switch, and then verify to return to the “Main

menu” on the LCD display.
When this check is failure, displayed “NG” on LCD, and beep