Pll adjustment, 2 pll unit adjustment – Icom IC-M802 User Manual

Page 20

Advertising
background image

4 - 3

4-2 PLL UNIT ADJUSTMENT

LPL LOCK
VOLTAGE

HPL LOCK
VOLTAGE

REFERENCE
FREQUENCY

1

2

1

2

1

2

• Operating frequency : 0.5000 MHz
• Mode

: J3E

• Receiving

• Operating frequency : 0.4999 MHz
• Receiving

• Operating frequency : 29.9999 MHz
• Mode

: J3E

• Receiving

• Operating frequency : 0.0300 MHz
• Receiving

• Wait for 5 minutes after power ON.
• Terminate P5201 on the PLL unit to

ground with a 50

Ω resister.

• Receiving

PLL

PLL

PLL

Connect a digital multi
meter or oscilloscope
to check point
CP5301.

Connect a digital multi
meter or oscilloscope
to check point
CP5401.

Connect an RF volt-
meter to check point
P5201.

Connect a frequency
counter to check point
P5201.

1.0 V

Less than 4.0 V

4.2 V

More than 0.8 V

Maximum level

63.999990 MHz

([USA], [CAN])

64.000000 MHz

([OTH])

PLL

PLL

PLL

C5305

Verify

C5521

Verify

L5203,

L5204

X5251

([USA],

[CAN])

C5294

([OTH])

ADJUSTMENT

ADJUSTMENT CONDITIONS

UNIT

LOCATION

VALUE

UNIT

ADJUST

MEASUREMENT

ADJUSTMENT