Interfaces, Rcm-810 general specifications, Accessories – I.R.I.S. RCM-810 User Manual

Page 2: Pole euro block connector for gpio control port, Controller

Advertising
background image

GmbH • Hirschberger Ring 45 • 94315 Straubing • Telefon (09421) 706-0 • Telefax (09421) 706-265

Subject to change without prior notice. Printed in Germany Vs 02 10.03.2009 D367600 / F01U108146

Technical Specifications

RCM-810 Block Diagram

NETWORK AND GENERAL FEATURES

Remote Control and Software

IRIS-Net, Multiple PCs possible, MS Windows 2000, XP, Vista

Maximum Configuration

250 Amplifiers in total, 100 Amplifiers per CAN bus, 1000 meter cable run

Amplifier Supervision

Operation mode, temperature, output voltage and current, impedance of
connected speakers, protection mode status, pilot tone detection

Network Supervision

CAN bus failures, defective or missing amplifiers, bandwidth, failure protocol
and messaging

INTERFACES

CAN

10…500 kbaud, 2 x RJ-45 (IRIS-Net Control)

GPIO Control Port

2 x 3-pole Euro block
2 Control Inputs
2 Control Outputs
2 Reference Outputs (+5 V, 200 mA / GND)

RCM-810 GENERAL SPECIFICATIONS

Supply Voltage/Current

+5 V DC / 320 mA
+15 V DC / 80 mA
-15 V DC / 80 mA

Power Consumption

4 W

Operating Temperatur Range

0 °C...40 °C

Dimensions (W x H x D)

103.5 x 37 x 103 mm

Weight

115 g

ACCESSORIES

3-pole Euro block connector

For GPIO Control Port

Controller

SRAM

Latch

CAN

CAN-LED

FRAM

/ATMEL_PROG

/RCM_EN

RCM_CLK

RCM_MOSI

RCM_MISO

/RCM_DETECT

REMOTE

CAN BUS

G

alv

an

ic

Is

o

la

tio

n

P/S

DC

DC

CAN

ADDRESS

+5V

CAN-LED

0

2

1

3 4 5 6

7

8

9

A

B

C

D

E

F

0

2

1

3 4 5 6

7

8

9

A

B

C

D

E

F

CONTROL

PORT

+5V

DGND

+5V

Reset

Watchdog

+5V

Test

AMP ID

POWER ON

MUTE A / B

STANDBY

LIMIT /

PROTECT /

REDUCTION

CURRENT A- / B-

CURRENT A+ / B+

VOLTAGE A- / B-

VOLTAGE A+ / B+

AGND

+15V

-15V

U-TEMP

ADC

Only 2 Channel AMP

IrisNet LED

+15V

AGND

-15V

TEMP_Board

BRIDGED

POWER_GOOD

Pilot Tone

Detection

INIT

Advertising