IBM A40 TYPE 6840 User Manual

Page 61

Advertising
background image

Diagnostic Error Code

FRU/Action

175-199-XXX
Thermal Sensor(s) test failed, cause
unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error

1.

Check fans

2.

Check Power supply

3.

Microprocessor

4.

System board

185-000-XXX
Asset Security Test Passed

1.

No action

185-XXX-XXX
Asset Security failure

1.

Flash system

2.

System board

185-278-XXX
Asset Security Chassis Intrusion

1.

Assure Asset Security Enabled

2.

C2 Cover Switch

3.

System board

201-000-XXX
System Memory Test Passed

1.

No action

201-XXX-XXX
System Memory error

1.

Replace the memory module called out
by the test

2.

System board

202-000-XXX
System Cache Test Passed

1.

No action

202-XXX-XXX
System Cache error

1.

Cache, if removable

2.

System board

3.

Microprocessor

206-000-XXX
Diskette Drive Test Passed

1.

No action

206-XXX-XXX
Diskette Drive error

1.

Diskette Drive Cable

2.

Check power supply voltages

3.

Diskette drive

4.

System board

215-000-XXX
CD-ROM Drive Test Passed

1.

No action

215-XXX-XXX
CD-ROM Drive error

1.

CD-ROM Drive Cable

2.

Check power supply voltages

3.

CD-ROM drive

4.

System board

217-000-XXX
Hard Disk Drive Test Passed

1.

No action

217-25X-XXX
217-26X-XXX
Hard Disk Drive (IDE) error

1.

Hard Disk Drive Cable

2.

Check power supply voltages

3.

Hard Disk drive (IDE)

4.

System board

Chapter 6. Symptom-to-FRU Index