IBM A40 TYPE 6840 User Manual

Page 66

Advertising
background image

POST Error Code

FRU/Action

08X
Check SCSI terminator installation.

1.

SCSI Cable

2.

SCSI Terminator

3.

SCSI Device

4.

SCSI Adapter

101
System board interrupt failure

1.

System Board

102
System board timer error

1.

System Board

106

1.

System Board

110
System board memory parity error

1.

Memory Module

2.

System Board

111
I/O channel parity error

1.

Reseat adapters

2.

Any adapter

3.

Riser card

4.

System Board

114
Adapter ROM error

1.

Adapter Memory

2.

System Board

3.

Riser card

129
Internal cache test error

1.

Processor

2.

L2 Cache Memory

3.

System Board

151
Real-time clock failure

1.

System Board

161
Bad CMOS battery

1.

Run Setup

2.

CMOS Backup Battery (see “Safety
Information” on page 125)

3.

System Board

162
Configuration mismatch

1.

Run Setup and verify Configuration

2.

Had a device been added, removed,
changed location? If not, suspect that
device.

3.

Power-on external devices first, then
power-on computer

4.

CMOS Backup Battery (see “Safety
Information” on page 125)
System Board

5.

System Board

6.

Riser card

162
And unable to run diagnostics

1.

Diskette Drive

2.

System Board

3.

Diskette Drive Cable

4.

Riser card

60