PD10E-X-X (en)

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

Do not exceed the maximum inlet air pressure as

stated on the pump model plate.

Be sure material hoses and other components are able

to withstand fluid pressures developed by this pump.

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

Sparks can ignite flammable material and vapors.

The pumping system and object being sprayed must be

grounded when it is pumping, flushing, recirculating or

spraying flammable materials such as paints, solvents,

lacquers, etc. or used in a location where surrounding

atmosphere is conducive to spontaneous combustion.

Ground the dispensing valve or device, containers, hos-

es and any object to which material is being pumped.

Secure pump, connections and all contact points to

avoid vibration and generation of contact or static spark.

Consult local building codes and electrical codes for

specific grounding requirements.

After grounding, periodically verify continuity of

electrical path to ground. Test with an ohmmeter

from each component (e.g., hoses, pump, clamps, con-

tainer, spray gun, etc.) to ground to insure continuity.

Ohmmeter should show 0.1 ohms or less.

Submerse the outlet hose end, dispensing valve or

device in the material being dispensed if possible.

(Avoid free streaming of material being dispensed.)

Use hoses incorporating a static wire.

Use proper ventilation.

Keep inflammables away from heat, open flames and

sparks.

Keep containers closed when not in use.

WARNING

Pump exhaust may contain contaminants.

Can cause severe injury. Pipe exhaust away from work

area and personnel.

In the event of a diaphragm rupture, material can be

forced out of the air exhaust muffler.

Pipe the exhaust to a safe remote location when

pumping hazardous or inflammable materials.

Use a grounded 3/8” minimum i.d. hose between the

pump and the muffler.

WARNING

HAZARDOUS PRESSURE. Can result in

serious injury or property damage. Do not service

or clean pump, hoses or dispensing valve while the

system is pressurized.

Disconnect air supply line and relieve pressure from

the system by opening dispensing valve or device and

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

HAZARDOUS MATERIALS. Can cause serious

injury or property damage. Do not attempt to return

a pump to the factory or service center that contains

hazardous material. Safe handling practices must comply

with local and national laws and safety code requirements.

Obtain Material Safety Data Sheets on all materials

from the supplier for proper handling instructions.

WARNING

EXPLOSION HAZARD. Models contain-

ing aluminum wetted parts cannot be used with III.-

Trichloroethane, Methylene Chloride or other Halo-

genated Hydrocarbon solvents which may react and

explode.

Check pump motor section, fluid caps, manifolds and

all wetted parts to assure compatibility before using

with solvents of this type.

WARNING

MISAPPLICATION HAZARD. Do not use

models containing aluminum wetted parts with food

products for human consumption. Plated parts can

contain trace amounts of lead.

CAUTION

Verify the chemical compatibility of the

pump wetted parts and the substance being pumped,

flushed or recirculated. Chemical compatibility may

change with temperature and concentration of the

chemical(s) within the substances being pumped,

flushed or circulated. For specific fluid compatibility,

consult the chemical manufacturer.

CAUTION

Maximum temperatures are based

on mechanical stress only. Certain chemicals will

significantly reduce maximum safe operating

temperature. Consult the chemical manufacturer for

chemical compatibility and temperature limits. Refer

to PUMP DATA on page 1 of this manual.

CAUTION

Be certain all operators of this equipment

have been trained for safe working practices,

understand it’s limitations, and wear safety goggles /

equipment when required.

CAUTION

Do not use the pump for the structural

support of the piping system. Be certain the system

components are properly supported to prevent stress

on the pump parts.

Suction and discharge connections should be flexible

connections (such as hose), not rigid piped, and should

be compatible with the substance being pumped.

CAUTION

Prevent unnecessary damage to the

pump. Do not allow pump to operate when out of

material for long periods of time.

Disconnect air line from pump when system sits idle

for long periods of time.

CAUTION

Use only genuine ARO replacement parts to

assure compatible pressure rating and longest service life.

NOTICE

RE-TORQUE ALL FASTENERS BEFORE

OPERATION. Creep of housing and gasket materials

may cause fasteners to loosen. Re-torque all fasteners

to insure against fluid or air leakage.

WARNING

= Hazards or unsafe practices which

could result in severe personal injury,

death or substantial property damage.

CAUTION

= Hazards or unsafe practices which

could result in minor personal injury,

product or property damage.

NOTICE

= Important installation, operation or

maintenance information.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.