TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.

Check tightness of (6) diaphragm screw.

Air bubbles in product discharge.

Check connections of suction plumbing.

Check“O” rings between intake manifold and inlet side

fluid caps.

Check tightness of (6) diaphragm screw.

Motor blows air or stalls.

Check (176) check valve for damage or wear.

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

Check air supply.

Check for plugged outlet hose.

Check for kinked (restrictive) outlet material hose.

Check for kinked (restrictive) or collapsed inlet

material hose.

Check for pump cavitation − suction pipe should be

sized at least as large as the inlet thread diameter of

the pump for proper flow if high viscosity fluids are

being pumped. Suction hose must be a non-collaps-

ing type, capable of pulling a high vacuum.

Check all joints on the inlet manifolds and suction

connections. These must be air tight.

Inspect the pump for solid objects lodged in the dia-

phragm chamber or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

8-5/16"

(211.1 mm)

1" A.N.S.I. / DIN Flange

Outlet

Inlet

Air Inlet 1/4 - 18 N.P.T.

14-1/8"

(358.5 mm)

6-31/32"

(176.6 mm)

16-1/32"

(407.0 mm)

16-1/32"

(407.0 mm)

8-1/32"

(203.4 mm)

13-25/32"

(349.8 mm)

2-11/32"

(59.4 mm)

1/2"

(12.7 mm)

5-1/32"

(127.6 mm)

7/16"

(11.1 mm)

6-9/32"

(159.6 mm)

10-1/16"

(255.3 mm)

4-1/16"

(103.0 mm)

16-1/32"

(407.3 mm)

Figure 4

Advertising