1 system specifications, 2 physical package, 1 system specifications 1.2 physical package – IBM P5 570 User Manual

Page 15

Advertising
background image

Chapter 1. General description

3

1.1 System specifications

Table 1-1 lists the general system specifications of a single p5-570 drawer.

Table 1-1 p5-570 specifications

1.2 Physical package

One p5-570 drawer is packaged in a 4U

2

rack-mounted enclosure, and it is available only in

the rack-mounted form factor. The following sections discuss the major physical attributes
that are found on the p5-570 building block, as shown in Table 1-2 on page 3.

Table 1-2 Physical packaging of the p5-570

Using the p5-570 building block, an installed system can be made of one to four building
blocks. To help ensure the installation and serviceability in non-IBM, industry-standard racks,
review the vendor’s installation planning information for any product-specific installation
requirements. The processor and SP Flex cables present an additional planning requirement.

Description

Range

Operating temperature

5 to 35 degrees C (41 to 95 F)

Relative humidity

8% to 80%

Maximum wet bulb

23 degrees C (73 F) (operating)

Noise level

6.5 bels (operating)

Operating voltage

200 to 240 V AC 50/60 Hz

Maximum power consumption

1,300 watts (maximum)

Maximum power source loading

1.37 kVA (maximum configuration)

Maximum thermal output

4,437 Btu

a

/hr (maximum configuration)

a. British Termal Unit (BTU)

2

One Electronic Industries Association Unit (1U) is 44.45 mm (1.75 in).

Dimension

One p5-570 building block

Height

174.1 mm (6.85 in)

Width

483 mm (19.0 in)

Depth

790 mm (31.1 in)

Weight

63.6 kg (140 lb)