IBM DR550 User Manual
Page 96
IBM System Storage DR550
Version 3.0 ------17 March 2006
Page 96
IBM Storage Systems
Copyright © 2006 by International Business Machines Corporation
2.
From the DS4000 Storage Manager client Enterprise Management window, go to Edit -> 
Configure Mail Server... at the upper left side. 
3. Enter your mail (SMTP) server address in the first line. This is the name of the mail server that
forwards the e-mail to the configured e-mail alert destination. This server must be able to route data to 
the network of the receiver. Enter a meaningful sender address information in the second line of the 
window as shown in Error! Reference source not found.. The sender’s e-mail address is displayed 
on every mail message that is sent to the configured e-mail alert destination. 
If you do not specify an SMTP server name, the Enterprise Management software attempts to 
send the e-mail using a mail server on the local Storage Management Station. The e-mail 
sender’s address required in the SMTP protocol must be specified or an error will result. 
4.
Click OK.
 
E-mail alert destination 
1.
Select the e-mail tab from the Edit -> Alert Destinations... menu screen at the DS4000 Storage 
Manager client Enterprise Management window. The Add/Edit Alerts dialog window opens. 
2.
Enter the e-mail address of the recipient for alert e-mail notification in the appropriate line. For 
example, [email protected] as shown below.