E.1 Access the controller

Please follow the steps to do the updating procedure.

Step1: Install MiniOS7 Utility

Step2: Use CA-0915 to connect 8430/8830/8KE4/8KE8 to COM1/2 of the

host PC.

Step3: Short Init* and Init*COM.

Step4: Power off and then power on the 8430/8830/8KE4/8KE8. The CPU doesn’t run

the autoexec.bat while power on stage.

+10V~30VDC

WER SUPPLY

PO

CA0915

841X/881X

DEVICE

RS-232

2

Power: 10~ 30 V

DC

4

3

CA-0915

8430/8830/8KE4/8KE8 User’s manual, Jan 2005, Version 1.0, 8MS-002-10 ----- 86