Appendix a: event messages and error codes, Table 15. event messages – Intel SROMBSASMR (AXXROMBSASMR) User Manual

Page 32

Advertising
background image

Appendix A: Event Messages and Error Codes

Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification

Intel order number E59029-003

26

Appendix A: Event Messages and Error Codes

This appendix lists the Intel

®

RAID Web Console 2 events that may appear in the event log.

The Intel

®

RAID Web Console 2 utility monitors the activity and performance of all controllers in

the server and any devices attached to them. When an “event” such as the completion of a
consistency check or the removal of a physical drive occurs, an event message is displayed in
the log, which appears at the bottom of the Intel

®

RAID Web Console 2 screen. The messages

are also logged in the Windows Application Log (Event Viewer). Error event levels are:

ƒ

Progress

: This is a progress posting event. Progress events are not saved in NVRAM.

ƒ

Information

: Informational message. No user action is necessary.

ƒ

Warning

: A component may be close to a failure point.

ƒ

Critical

: A component has failed, but the system has not lost data.

ƒ

Fatal

: A component has failed, and data loss has occurred or will occur.

ƒ

Dead

: A catastrophic error has occurred and the controller has failed. This is seen only

after the controller has been restarted.

The following table lists the Intel

®

RAID Web Console 2 event messages.

Table 15. Event Messages

Number

Type

Description

0

Information

Firmware initialization started (PCI ID %04x/%04x/%04x/%04x)

1

Information

Firmware version %s

2

Fatal

Unable to recover cache data from TBBU

3

Information

Cache data recovered from TBBU successfully

4

Information

Configuration cleared

5

Warning

Cluster down; communication with peer lost

6

Information

%s ownership changed from %02x to %02x

7

Information

Alarm disabled by user

8

Information

Alarm enabled by user

9

Information

Background initialization rate changed to %d%%

10

Fatal

Controller cache discarded due to memory/battery problems

11

Fatal

Unable to recover cache data due to configuration mismatch

12

Information

Cache data recovered successfully

13

Fatal

Controller cache discarded due to firmware version incompatibility

14

Information

Consistency Check rate changed to %d%%

15

Dead

Fatal firmware error: %s

16

Information

Factory defaults restored A249

17

Warning

Flash downloaded image corrupt

18

Critical

Flash erase error

19

Critical

Flash timeout during erase

20

Critical

Flash error

21

Information

Flashing image: %s

Revision

1.2