Appendix A: Event Messages and Error Codes

Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification

Intel order number E59029-003

30

Number

Type

Description

154

Warning

Battery relearn timed out

155

Information

Battery relearn pending: Battery is under charge

156

Information

Battery relearn postponed

157

Information

Battery relearn will start in 4 days

158

Information

Battery relearn will start in 2 days

159

Information

Battery relearn will start in 1 day

160

Information

Battery relearn will start in 5 hours

161

Warning

Battery removed

162

Warning

Current capacity of the battery is below threshold

163

Information

Current capacity of the battery is above threshold

164

Information

Enclosure (SES) discovered on %s

165

Information

Enclosure (SAF-TE) discovered on %s

166

Critical

Enclosure %s communication lost

167

Information

Enclosure %s communication restored

168

Critical

Enclosure %s fan %d failed

169

Information

Enclosure %s fan %d inserted

170

Warning

Enclosure %s fan %d removed

171

Critical

Enclosure %s power supply %d failed

172

Information

Enclosure %s power supply %d inserted

173

Warning

Enclosure %s power supply %d removed

174

Critical

Enclosure %s EMM %d failed

175

Information

Enclosure %s EMM %d inserted

176

Critical

Enclosure %s EMM %d removed

177

Warning

Enclosure %s temperature sensor %d below warning threshold

178

Critical

Enclosure %s temperature sensor %d below error threshold

179

Warning

Enclosure %s temperature sensor %d above warning threshold

180

Critical

Enclosure %s temperature sensor %d above error threshold

181

Critical

Enclosure %s shutdown

182

Warning

Enclosure %s not supported; too many enclosures connected to port

183

Critical

Enclosure %s firmware mismatch (EMM %d)

184

Warning

Enclosure %s sensor %d bad

185

Critical

Enclosure %s phy bad for slot %d

186

Critical

Enclosure %s is unstable

187

Critical

Enclosure %s hardware error

188

Critical

Enclosure %s not responding

189

Warning

SAS/SATA mixing not supported in enclosure; %s disabled

190 Warning

Enclosure

(SES)

hot plug on %s was detected

191

Information

Clustering enabled

192

Information

Clustering disabled

193

Information

PD too small to be used for auto-rebuild on %s

194

Information

BBU enabled; changing WT virtual disks to WB

195

Warning

BBU disabled; changing WB virtual disks to WT

196

Warning

Bad block table on %s is 80% full

197

Fatal

Bad block table on %s is full; unable to log block %lx

Revision