IBM x Series 200 User Manual
Page 103
 
Symptom-to-FRU index
95
114
(Adapter read-only memory 
error)
1.
Failing adapter
2.
Run diagnostics
129
(Internal cache error)
1.
Microprocessor
151
(Real time clock error)
1.
Run Diagnostics
2.
Battery
3.
System Board
161
(Real time clock battery error)
1.
Run Configuration/Setup
2.
Battery
3.
System Board
162
(Device Configuration Error)
Note:
Be sure to load the 
default settings and 
any additional 
desired settings; then, 
save the configura-
tion.
1.
Run Configuration/Setup
2.
Battery
3.
Failing Device
4.
System Board
163
(Real-Time Clock error)
1.
Run Configuration/Setup
2.
Battery
3.
System Board
164
(Memory configuration 
changed, see "Memory 
Settings" on page 31.)
1.
Run Configuration/Setup
2.
DIMM
3.
System Board
175
(Hardware error)
1.
System Board
176, 177, 178
(Security hardware error)
1.
Run Configuration/Setup
2.
System Board
184
(Power-on password 
corrupted)
1.
Run Configuration/Setup
2.
System Board
185
(Drive startup sequence 
information corrupted)
1.
Run Configuration/Setup
2.
System Board
186
(Security hardware control 
logic failed)
1.
Run Configuration/Setup
2.
System Board
Error Code/Symptom
FRU/Action