IBM x Series 200 User Manual
Page 104
 
96
Hardware Maintenance Manual: xSeries 200
187
(VPD serial number not set.)
1.
Set serial number in Setup
2.
System Board
188
(Bad EEPROM CRC #2)
1.
Run Configuration/Setup
2.
System Board
189
(Three attempts were made to 
access the server with invalid 
passwords)
1.
Run Configuration/Setup, enter the administrator password
2.
System Board.
201
(Memory test error, see 
"Memory Settings" on page 
31.) If the server does not 
have the latest level of BIOS 
installed, update the BIOS to 
the latest level and run the 
diagnostic program again.
1.
Run memory diagnostics.
2.
DIMM
3.
System Board
229
(Cache error)
1.
Microprocessor
289
(DIMM has been disabled by 
user or system, see "Memory 
Settings" on page 31.)
1.
Run Configuration/Setup, if disabled by user
2.
Disabled DIMM, if not disabled by user.
301
(Keyboard or keyboard 
controller error)
1.
Keyboard
2.
System Board
303
(Keyboard controller error)
1.
System Board
2.
Keyboard
602
(Invalid diskette boot record)
1.
Diskette
2.
Diskette Drive
3.
Cable
4.
System Board
604
(Diskette drive error)
1.
Run Configuration/Setup and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
662
(Diskette drive configuration 
error)
1.
Run Configuration/Setup and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
Error Code/Symptom
FRU/Action