28

5

SCAN OPERATION

Setting scan edges

Settings such as frequency range, receive mode, tuning step,
etc. must be set in advance. Up to 20 settings can be pro-
grammed.

q

Call up the setting screen if it is not displayed.

• For the multi-function receiver screen, click the [SET] button.
• For the simple function receiver screen, click the [MENU] button

and select the ‘Function Setting (SET).’ When the scan controller
screen is in use, click the [SET] button on the screen.

w

Click the [Program SCAN] tab to show the program list.

e

Click a start frequency cell in the [START] column to se-
lect the data input condition.

• When a cell is clicked, the scan edges of the line are automati-

cally set as scan edges.

r

Input the start frequency into the selected cell from the
keyboard, then push [Enter] (data appears automatically in
other cells when new range is entered.).

• Data must be set in this cell or the [END] cell before data can be

set in other cells.

• To erase the data, push the [Delete] key after selecting a [START]

or [END] cell.

t

Set data into other cells as desired, then click the close
([

"

]) button to close the program list.

Selected scan edge number

Set other data, if desired

Scan edge frequency