The unit has an alarm function to protect your ship from collisions. If other ships or islands, etc. come into the pre-
programmed alarm zone, the function alerts you with an alarm. You can set the desired range and bearing for an
alarm zone. While the alarm function is activated, the power save function turns the CRT OFF until an alarm is
given, to conserve power.

Alarm zone setting

D Setting and using the alarm function

q Push [+]/[

] or [–]/[

] to select the desired

range.

w Push [Ω ≈ Щ Ъ] to set the cursor to the starting

point of the alarm zone.

e Push and hold [ALM]/[

] for 1 sec. to enter the

alarm zone setting.

• The starting zone appears on the screen. (Fig. 1)

r Push

[

Ω ≈

]

to adjust an angle and push

[

Щ Ъ

]

to

set the distance of the alarm zone.

• The selected alarm zone appears.

t Push [ALM]/[

] to fix the alarm zone and activate

the alarm function.

• “

ALM

” appears on the bottom of the screen.

• The selected alarm zone remains.

y If a target comes into or goes out of the alarm zone,

an alarm beep is emitted.

• Push [ALM]/[

] to cancel the alarm signal and func-

tion .

u To deactivate the alarm function, push [ALM]/[

].

• “ALM” and alarm zone disappear from the screen.

i To activate the alarm function again with the same

programmed zone, push [ALM]/[

].

• “ALM” and pre-programmed alarm zone appears. (Fig. 2)

Using the function with power saver
To activate the power save function, push and hold [TX
(SAVE)]/[

] for 1 sec. while the alarm function

is turned ON.

• The CRT display turns OFF.
• When a target comes into the alarm zone, an alarm sig-

nal is emitted, the CRT display turns ON and the power
save function is cancelled.

Zone alarm setting

Zone alarm beep is emitted when the target comes
into the zone, or the target goes out of the zone. (p. 6)

q Push [MENU]/[

] several times to call up the

FUNCTION menu.

w Push [Ú] until the “ZONE ALARM” section becomes

highlighted.

e Push [Ω ≈] to select IN or OUT

• IN

: Alarm sounds when the target comes into the

zone. (see Fig. 3)

• OUT: Alarm sounds when the target goes out of the

zone.

Alarm sounds when the target
comes into the zone.

Alarm zone

Fig. 3

Target (other ship, etc.)

3/4

(0.25)

TVECT

3M

0189NM

NM

CURS\

SOG177KT

H UP

0525˚T

HDG2739˚T

IR

ES

EBL1
EBL2
WPT

VRM1
VRM2

CURS 34˚ 3772N 135˚ 3442E

GYRO

GPS

ALM

3/4

(0.25)

TVECT

3M

0397NM

NM

CURS\

SOG177KT

H UP

3143˚T

HDG2739˚T

IR

ES

EBL1
EBL2
WPT

VRM1
VRM2

CURS 34˚ 3772N 135˚ 3442E

GYRO

GPS

Push

[Ω ≈ Щ Ъ]

“ALM”
appears

Fig. 1

Fig. 2

ALARM FUNCTION