Installation and connections, Connecting the units, Power source requirement – Icom MR-1000TTM User Manual

Page 28: Ground connection

Advertising
background image

Connecting the units

NMEA1 connection

NMEA2 connection

Power source requirement

D DC power source

The radar is designed for connection to any power
source if the voltage is 10.2–42 V DC, so that a 12, 24,
or 32 V DC battery can be used without a DC-DC con-
verter, or any internal modifications.

DC power cable connection
Connect the supplied DC power cable as shown in the
diagram.

Ground connection

To prevent electrical shocks and other problems, ground the display unit through the [GND] terminal on the unit’s
rear panel. For best results, connect a heavy gauge wire or strap to the nearest grounding point on the boat. The
distance between the [GND] terminal and the ground point should be as short as possible.

CAUTION

:

Incorrect cable connection may dam-

age the radar.

DC input

Ground

q N TXT
(NMEA 2 output)

w RXD

i GND

u N.C

y AUX input (–); CLOCK
or N+1(–) data input

t AUX input (+); CLOCK
or N+1(+); data input

r NMEA 1 input (–)
or AUX input (–); DATA

e NMEA 1 input (+)
or AUX input(+); DATA

NMEA1:
Bearing data input

NMEA2:
NMEA 0183 data input
Speed sensor input

+

;

Ground

Power supply
10.2 to 42 V DC

Red:

Black: _

PWR

GND

NEVER connect any-
thing other than the sup-
plied scanner unit.

Supplied scanner unit

9

INSTALLATION AND CONNECTIONS

24

q NMEA 2
output (+)
w NMEA 2
output (–)
e NMEA 2
input (+)

u GND (Speed sensor)

y Speed sensor
input

t Regulated 12 V output.
(20 mA Max.)
r NMEA 2 input (–)

MR-1000R2_T2.qxd 04.2.24 10:22 Page 24