Ac line – Intelligent Motion Systems Modular LYNX System User Manual

Page 14

Advertising
background image

1 - 14

Modular LYNX System 12.05.2003

S t a n d - a l o n e o r w i t h O p t i o n a l I / O M o d u l e s

+ 1 2 t o + 7 5 V D C S u p p l y

A +12 to +75VDC unregulated supply connected to P1 provides power to the LYNX Control Module and
any optional I/O modules. As in the LYNX Controller with Driver (s) Configuration, pins 5 (Ground) and 6
(+5VDC) on connector P2 of the Control Module becomes a +5VDC (150mA, internally limited) regulated
output.

+ 5 V D C S u p p l y

A +5VDC ±5% regulated supply connected to
pins 5 (Ground) and 6 (+5VDC) on connector P2
provides power to the LYNX Control Module
and any optional I/O modules. Figure 4.3. It is
assumed that external drives are being used and
power is supplied to these drives separately.
The LYNX Controller internally limits the current
to 800mA. While the LYNX Controller and I/O
Modules will only require 368mA, a fully
configured LYNX System utilizing the outputs
may require up to 800mA.

Figure 4.3: Stand-alone Power Configuration: 5 VDC

DIR+

DIR-

SCK-

SCK+

GND

+5V

RX-

RX+

TX-

TX+

CGND

RX

TX

22

21

23

24

25

26

31

32

33

34

35

36

IG

123

45

6

123

4
5
6

123

4
5
6

22

21

23
24
25
26

31
32
33
34
35
36

GND

V+

A1

A0

A2
PT

HI

UG

TM

+5VDC ±5%

Regulated Supply

(Up to 800mA)

Figure 4.2: Stand-alone Power Configuration: 12 - 75 VDC Supply

ISP200-4

DIR+

DIR-

SCK-

SCK+

GND

+5V

RX-

RX+

TX-

TX+

CGND

RX

TX

22

21

23

24

25

26

31

32

33

34

35

36

IG

12

3

4

5

6

12

3

4
5
6

12

3

4
5
6

22

21

23
24
25
26

31

32

33

34

35

36

GND

V+

A1

A0

A2
PT

HI

UG

TM

AC Line

+12 to +75VDC

Power Supply

(IMS ISP 200-4 Shown)

+5VDC, 150mA

Internally Limited

Output

!

!

Ensure that the DC Output of
the Supply Does Not Exceed
the Maximum Driver Input Voltage!

All Power Supply Wiring Should Be
Shielded Twisted Pair to Reduce
Electrical Noise!

Advertising