T h e D i f f e r e n t i a l D i g i t a l I / O M o d u l e

S e c t i o n O v e r v i e w

A LYNX system may contain an optional Differential I/O Module (IMS Part# LX-DD100-000) which provides
six (6) high speed differential I/Os. These I/Os can be used as clock inputs or outputs or general purpose
I/O. Along with the differential motion I/Os (P1, pins 1 – 4) of the LYNX Control Module, these I/O make up
the Group 1 signal set. Each signal pair is a 0 to 5VDC input or output. When used as an input or an output
a single ended or differential configuration is accommodated.

!

Hardware Specifications

!

Environmental Specifications

!

Mechanical Specifications

!

Power Requirements

!

Pin Assignments

!

Input Specifications

!

Input Filtering

!

Output Specifications

H a r d w a r e S p e c i f i c a t i o n s

E n v i r o n m e n t a l S p e c i f i c a t i o n

Ambient Operating Temperature .............................................. 0 to 50 degrees C
Storage Temperature ................................................................ -20 to 70 degrees C
Humidity .................................................................................. 0 to 90% non-condensing

M e c h a n i c a l S p e c i f i c a t i o n

0.39

(9.9)

4.39 max

(111.5)

3.75

(95.3)

0.9 max

(22.9)

Figure 10.1 : LYNX Differential I/O Module Dimensions

Dimensions in Inches (mm)