Using

the

SCSISelect

Utility

program

(some

models)

Use

the

SCSISelect

Utility

program

to

configure

SCSI

devices.

Starting

the

SCSISelect

Utility

program

Complete

the

following

steps

to

start

the

SCSISelect

utility

program:

1.

Turn

on

the

server.

2.

When

the

prompt

<<<

Press

<CTRL><A>

for

SCSISelect

Utility!

>>>

appears,

press

Ctrl+A.

If

you

have

set

an

administrator

password,

you

are

prompted

to

type

the

password.

3.

Use

the

arrow

keys

to

select

a

choice

for

which

you

want

to

change

settings,

and

press

Enter.

4.

When

the

prompt

Would

you

like

to

configure

the

SCSI

controller

or

run

the

SCSI

disk

utility?

appears,

make

your

selection

and

press

Enter.

5.

Use

the

arrow

keys

to

select

a

choice

from

the

menu.

6.

Follow

the

instructions

on

the

screen

to

change

the

settings

of

the

selected

items,

and

press

Enter.

SCSISelect

Utility

menu

choices

The

following

choices

are

on

the

SCSISelect

Utility

menu:

v

Configure/View

SCSI

Controller

Settings

Select

this

choice

to

view

or

change

SCSI

controller

settings.

To

reset

the

SCSI

controller

to

its

default

values,

press

F6

and

follow

the

instructions

on

the

screen.

You

can

view

or

change

the

following

controller

settings:

SCSI

Controller

ID

Select

this

choice

to

view

the

SCSI

controller

ID,

which

is

typically

7.

SCSI

Controller

Termination

This

choice

is

set

to

Enabled

and

cannot

be

changed.

Boot

Device

Configuration

Select

this

choice

to

configure

startable-device

parameters.

You

must

know

the

SCSI

ID

of

the

device

that

you

want

to

configure.

SCSI

Device

Configuration

Select

this

choice

to

configure

SCSI-device

parameters.

You

must

know

the

SCSI

ID

of

the

device

that

you

want

to

configure.

Note:

The

Maximum

Sync

Transfer

Rate

represents

the

transfer

rate

for

Ultra

SCSI

devices.

-

The

transfer

rate

for

Ultra3

SCSI

LVD

devices

is

160

MBps

-

The

transfer

rate

for

Ultra2

SCSI

LVD

devices

is

80

MBps

-

The

transfer

rate

for

Fast

SCSI

devices

is

20

MBps

28

xSeries

206

Type

8482:

User’s

Guide

Advertising