6. Connect any other signal cables for I/O devices to the correct ports.

7. Check that all signal cables are installed and seated in the correct ports.

8. If you are installing the printer on an integrated unit:

a. Pull out the locking lever at the left side of the system unit. (wide systems

only)

b. For single-station printers, place the printer in the square-shaped filler

panel.

c. Route the keyboard cable to the side of the tab as shown in Figure 13 on

page 25.

d. Route all cables attached to the printer through the center opening of the

system unit and place the printer (with its filler panel, if it is a single-station
printer) on the system unit.

e. If you have additional fillers to install, go to “Installing the fillers” on page

24.

f. Lift the system unit rear cover and attach any cables from the printer to the

system unit. (If this is a EIA-232-attached printer, reattach the brick power
cord if you had to detach it to route it through the center opening.)

9. Power on the printer by either:

v

Connecting the brick power supply cable to a properly wired and grounded
power source and powering it on.

v

Powering on the POS system unit for an RS-485-attached printer.

Attention:

Never connect both voltage sources to the printer at the same

time, even if one of the sources is powered off. Potential system damage
could occur under these conditions.

10. For single-station SureMark printers, turn on the power on/off switch on the

printer.

Cash drawer cable

Power cord

EIA-232 cable

Cash drawer cable

RS-485 cable

Figure 8. EIA-232 and RS-485 cable routing for single-station SureMark printers