Chapter 5. testing and problem analysis, Testing the printer, Chapter 5, “testing and problem analysis – IBM SUREMARK TI8 User Manual

Page 83

Advertising
background image

Chapter 5. Testing and problem analysis

DANGER

To avoid a shock hazard, do not connect or disconnect any cables
or perform installation, maintenance, or reconfiguration of this
product during an electrical storm.

DANGER

To avoid shock hazard:

The power cord must be connected to a proper ly wired and
earthed receptacle.

Any equipment to which this product will be attached must also
be connected to properly wired receptacles.

Note: For translations of these safety notices, see IBM Safety Information—Read

This First, GA27-4004.

Testing the printer

When you power ON the SureMark printer, it runs a power-on self-test (POST). If
the POST finds no errors, the printer is ready for operation. Follow this procedure to
determine if there are errors.

Note: Never connect or disconnect the printer when power is applied (when LEDs

are ON).

1. If the printer is powered ON, power OFF the printer and power it ON again.

v

If the printer is attached to the system with the EIA-232 cable or the standard
USB cable with a power brick, disconnect the power cord, then reconnect the
power cord to a properly wired and grounded power source.

v

If the printer is attached to the system with the RS-485 cable, power OFF the
POS system, and then power ON the system, which also powers ON the
printer.

v

If the printer is attached to the system with a powered USB cable, the USB
attached printer can be hot-plugged.

Updated April 2, 2009

© Copyright IBM Corp. 1997, 2006

61