18 rolling bios bank selection jumper – Intel SE7525GP2 User Manual

Page 162

Advertising
background image

Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS Connector Definitions and Pin-Outs

Revision 2.0

162

Figure 19. System Configuration Jumpers (J17)

The following table describes each jumper option.

Table 95. Configuration Jumper Options

Option

Description

CMOS Clear If pins 1 and 2 are jumpered (default), preservation of configuration CMOS through system reset is

controlled by the mBMC. If pins 2 and 3 are jumpered, CMOS contents are set to manufacturing
default during system reset.

Password
Clear

If pins 1 and 2 are jumpered (default), the current BIOS Setup Utility passwords are maintained during
system reset. If pins 2 and 3 are jumpered, the Administrator and user passwords are cleared on
reset.

Recovery
Boot

If pins 1 and 2 are jumpered (default) the system will attempt to boot using the BIOS programmed in
the Flash memory. If pins 2 and 3 are jumpered, the BIOS will attempt a recovery boot, loading BIOS
code from a floppy disk into the Flash device. This is typically used when the BIOS code has been
corrupted.

7.18 Rolling BIOS Bank Selection Jumper

An additional 3-pin jumper header (J26) is provided to support the Rolling BIOS functionality.
This jumper is located near the processor 2 VRD heatsink and the SATA connectors on the
board. The jumper provides the option to force the board to boot from Bank 0 as part of the
Rolling BIOS feature. The figure below shows the factory default location for the jumper option.

Figure 20. BIOS Bank Jumper (J26)

Advertising