63

9

CONNECTIONS AND MAINTENANCE

9

r Return the cables and screws to the original position.

• Be sure not upside down the flat cable.

CAUTION:

• When re-assembling the case and tightening the screws,

you must keep the specified torque (0.5±0.07 N.m). Oth-
erwise the transceiver may be damaged (torque too high)
or lose waterproof efficiency (torque too low).

• When uninstalling the optional unit, remove it vertically.

Wiggling the unit from side to side may damage the op-
tional unit's connector.

HM-162/HM-157 installation

The optional HM-157 can be connected to the transceiver di-
rectly, as well as via the supplied connection cable for longer
distance remote operation. The connector of the connection
cable can be installed into a cabinet, wall, etc., as a built-in plug.

• The optional HM-162 should be installed to the transceiver using

the supplied connection cable.

For longer distance remote operation, the optional extension
cable, OPC-1541/OPC-999* (6 m; 20 ft/connecting between
transceiver and the connection cable), is available, and up to
two OPC-1541/OPC-999* can be added.
*OPC-1541 : For the HM-162

OPC-999 : For the HM-157
Do not connect the HM-162 to the OPC-999, and the HM-
157 to the OPC-1541.

HM-157

HM-162