7.2.3

SCSI Enclosure Management

SCSI enclosure management allows the SCSI Backplane Board to report hot-swap SCSI hard
disk drive status via the SCSI bus. This information is normally consumed by a RAID controller
that supports enclosure management; the optional ROMB accessory supports this feature. The
SCSI enclosure management subsystem consists of a Qlogic GEM359 controller, flash, and
PLD.

PLD

(LC4128V)

LVD SCSI BUS DATA 0..7

LVD SCSI BUS CONTROL

ENCLOSURE

MANAGEMENT

CONTROLLER

(Qlogic* GEM359)

Ad

dres 0..16

THERMAL

SENSOR

(DS75)

RESET

Control

FLASH

FRU

(24C02)

I

2

C

DAT

A

Drive an

d

LED

contr

ol

Figure 31. Enclosure Management Signal Flow Diagram

7.2.3.1

Qlogic GEM359 Enclosure Management Controller

The GEM359s send board and drive information to both the SCSI and IPMB bus. The GEM359s
also act on requests from both the SCSI bus and global I

2

C bus. GEM359s GPIOs send LED

information to the PLD.

7.2.3.2 4-Mb

Flash

The GEM359s code is stored in a 4-Megabit FLASH (512K x 8). The FLASH boot block is in the
top 16k of the block. The boot block is write-protected. Non-protected FLASH can be updated
through the IPMB bus.

7.2.3.3 PLD

The PLD governs the SCSI power control circuit and controls the LEDs. The PLD is an In-System
Programmable (ISP) with an 8-pin header connector.