Intel SR6850HW4 User Manual

Page 96

Advertising
background image

SCSI Backplane Board Intel® Server Platform SR6850HW4 TPS

Revision

1.0

Intel order number D23151-001

84

7.4.1.2

Hot-Swap SCSI Hard Disk Drive Supplied Power

Hot-swap SCSI hard disk drives must fall within the power limits shown in Table 51. The SCSI
Backplane Board works with drives that meet the following requirements.

Table 51. SCSI Backplane Board Board Power Limits per Drive

Device constraint

+5 V

+12 V

Peak start current

0.73A

1.5A

Max operating current 0.81A 1.15A
Average idle

0.68A

0.61A

7.4.1.3

Power Supply Requirements

The external and internal power supply must meet the following requirements:

ƒ

Rise time of less than 50ms (for all voltages).

ƒ

Delay of 5ms (minimum) from valid power to power good.

See Table 52 for voltage regulation requirements.

Table 52. DC Voltage Regulation

DC Voltage

Acceptable Tolerance

+5V ±

5%

+12V ±

5%

+3.3V ±

5%

+3.3V

stby

±

5%

+1.8V ±

5%

Advertising