Thermal/Mechanical Reference Design

32

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Note:

Intel does not enable reference heatsink for the Quad-Core Intel® Xeon®

Processor X5482

with 150W TDP. The Intel 2U CEK is capable of meeting the

thermal specification when local ambient temperature (T

LA

) is maintained at

or below 35°C.

2.3

Fan Fail Guidelines

Under fan failure or other anomalous thermal excursions, Tcase may exceed Thermal
Profile [Thermal Profile B for Quad-Core Intel® Xeon® Processor X5400 Series] for a
duration totaling less than 360 hours per year without affecting long term reliability
(life) of the processor. For more typical thermal excursions, Thermal Monitor is
expected to control the processor power level as long as conditions do not allow the
Tcase to exceed the temperature at which Thermal Control Circuit (TCC) activation
initially occurred. Under more severe anomalous thermal excursions when the
processor temperature cannot be controlled at or below this Tcase level by TCC
activation, then data integrity is not assured. At some higher threshold THERMTRIP#
will enable a shut down in an attempt to prevent permanent damage to the processor.
Thermal Test Vehicles (TTVs) may be used to check anomalous thermal excursion
compliance by ensuring that the processor Tcase value, as measured on the TTV, does
not exceed Tcase_max [Tcase_max_B for Quad-Core Intel® Xeon® Processor X5400
Series] at the anomalous power level for the environmental condition of interest. This
anomalous power level is equal to 80% of the TDP limit for Quad-Core Intel® Xeon®
Processor X5400 Series with 120W TDP and 90% of the TDP limit for Quad-Core Intel®
Xeon® Processor E5400 Series with 80W TDP.

Note:

Fan Failure Guidelines apply only to SKUs which have Thermal Monitor2 enabled.

Table 2-5.

Intel Reference Heatsink Performance Targets for the Quad-Core Intel®

Xeon® Processor E5400 Series

Parameter

Maximum

Unit

Notes

Altitude

Sea-Level

m

Heatsink designed at 0 meters

T

LA

40

°C

TDP

80

W

1U CEK

T

CASE_MAX

67

°C

Airflow

15

25.5

CFM

m

3

/ hr

Airflow through the heatsink fins

Pressure Drop

0.331

82.4

Inches of H

2

O

Pa

ψ

CA

0.246

°C/W

Mean + 3σ

1U Alternative Heatsink

T

CASE_MAX

67

°C

Airflow

15

25.5

CFM

m

3

/ hr

Airflow through the heatsink fins

Pressure Drop

0.331

82.4

Inches of H

2

O

Pa

ψ

CA

0.331

°C/W

Mean + 3σ

Advertising