Intel cPCI-7200 User Manual

Page 64

Advertising
background image

56

C/C++ Libraries

5.27 _7200_DI_Timer

@ Description

This function is used to set the internal timer pacer for digital input. There are
two configurations for the internal timer pacer:

1. Non-cascaded (One COUNTER 0 only)

Counter 0

CLK0
GATE0

OUT0

8254 Timer/Counter

4MHz Input

Digital Input Trigg

Timer pacer frequency = 4Mhz / C0

2. Cascaded (TIME2 cascaded with COUNTER0)

Counter 0

Counter 1

Counter 2

CLK0
GATE0

OUT0

CLK1
GATE1

CLK2
GATE2

OUT1

OUT2

8254 Timer/Counter

4MHz Input

Digital Input Trigg

Timer pacer frequency = 4Mhz / (C0 * C2)

@ Syntax

Visual C++ (Windows 95)

int W_7200_DI_Timer (U16 c0, U16 c2, Boolean mode)

Visual Basic (Windows 95)

W_7200_DI_Timer ( ByVal c0 As Integer, ByVal c2 As Integer,

ByVal mode As Byte ) As Long

C/C++ (DOS)

int _7200_DI_Timer (U16 c0, U16 c2, Boolean mode)

@ Argument

c0:

frequency divider of Counter #0. Valid value ranges from 2 to 65535.

c2:

frequency divider of Counter #2. Valid value ranges from 2 to 65535.

Note

: Since the Integer type in Visual Basic is a signed integer. Its range is

within -32768 and 32767. In Visual Basic, to set c0 or c2 to a value
larger than 32767, set it as the intended value minus 65536. For
example, to set c0 as 40000, set c0 as 40000-65536=-25536.