8.1D No Heat Or Not Enough Heat

• Symptoms: Circulation pump (heating pump) is turning, panel heat indicator not lit,
panel is fl ashing FL1.

Standard Troubleshooting Approach

No

Verify hot tub is in
standard filtration mode
(page 21). Remove flow
wires from switch.
Increase set temperature
to Initiate a heat call, then
jumper flow switch wires
together (see fig. G).
Does heat indicator
appear and FL1 error
message disappear?

Is the circulation pump
(Heat Pump) moving
water?

Remove flow switch and

inspect for debris

blockage. Remove

blockage or replace

switch. Install flow

switch with arrow

pointing in direction of

flow. Make sure magnet

arm doesn’t bottom out

in fitting (fig. J).

1. Remove filter and

allow air to bleed out

of cartridge.

2. Check for proper

water level.

3. Check for clogged /

excessively dirty

filter.

4. Is pump moving

water?

No

No

No

Yes

Yes

Yes

Yes

Yes

Remove flow switch

connector from circuit

board at point 11 (fig. H).

Place jumper across

exposed connector pins*.

Does heat indicator

appear and FL1 error

message disappear?

*Lightly scrape contact pins at

point 11 with a razor blade or

sandpaper to remove conformal

coating or oxidation from contact

surface.

Replace circuit board.

Repair or replace flow
sensor cable.

Clean connectors between
flow cable and switch.


See section 8.10 (pg. 42)

Test flow switch with

ohmmeter for continuity (0)

across switch terminals

(fig. I). Does meter read

continuity

(0) with pump on?

No

Danger: Electrical Shock Hazard Exists!
High Voltage Present On Circuit Board. Use Ex-
treme Caution While Servicing Circuit Board.

fig. G

fig. H

fig. I

Temporarily Jumper

Flow Switch Cable

Wires Together as Shown.

fig. J

FLOW

Incorrect

Orientation

Correct

Orientation

FLOW

Pipe

End View

correct

incorrect

Arrows

not

aligned

Arrows

aligned

Temporarily

Short Pins

with Jumper

#6560-864

Flow

Cable

22

23

Infinite

Continuity 0

Pump off

Pump on

Open

Closed

Jumper