A11.0 load box connection diagrams – Jacuzzi j315 User Manual

Page 52

Advertising
background image

52

A11.0 Load Box Connection Diagram For J-335, J-345 (240 VAC only, 60Hz)

Red

Pigtail

Neutral Bus

Ground

TB2

TB1

Black

Green

Main

Service

Panel

with

GFCI

Hot Tub

Load Box

2-Pole

GFCI

Breaker

Ground

J-335, J-345 (240 VAC Only)

2-Pole Circuit Breaker with 2-Wire Grounded Load Connection

(3 Wires to Hot Tub, 2-Hot, 1-Ground)

White

Black

Red

240 VAC/120 VAC

A

No Load Neutral Wire

Note: service disconnect not
shown in this diagram.

B

R

Red

Red (Hot)

Pigtail

Neutral Bus

Ground

TB2

Black

Black (Hot)

Green

GFCI Sub Panel*

Main Panel*

Hot Tub Load Box

2-Pole

GFCI

Breaker

Ground

No Load Neutral Wire

J-335, J-345 (240 VAC Only)

Main Panel with Secondary GFCI Sub-Panel Using a

2-Pole GFCI Breaker with 2-Wire Grounded Connection

(3 Wires to Hot Tub, 2-Hot, 1-Ground)

B

TB1

White (Neutral)

Green (Ground)

*GFCI Sub Panel commonly
used when recommended GFCI
does not install in Main Panel.

Note: service disconnect not
shown in this diagram.

B

R