8 weak or surging jets – Jacuzzi j315 User Manual

Page 40

Advertising
background image

40

8.8 Weak Or Surging Jets
Weak or surging jets are usually caused by an insuffi cient water supply to the pump or
a clogged or broken impeller. The water level may simply be too low, or there may be an
obstruction in the water fl ow path to the pump or in the pump’s impeller. Before making
a service call, ask the customer to verify that all jets are open and that there is suffi cient water in the
hot tub.

Suggested Spare Parts (Page 59): Filter, pump.

Standard Troubleshooting Approach

Remove debris or
loose foreign object.

No

No

No

No

Yes

Yes

No

Yes

Yes

Yes

Is water level
OK?

Are filter cartridges
clogged or dirty?

Clean or replace
filter cartridges.

Adjust water
level.

Are the filters installed
correctly?

Remove debris or
replace broken
impeller

Take pump housing
apart. Is debris
present in pump
impeller? Is the
impeller broken?

Is there debris or a
loose foreign object
between the filters
and pump input?

If pump suction line is
clear, check for
blockage in plumbing
on the return side of
pump. Call Jacuzzi
Premium Technical
Support for assistance
in performing this
verification step.

Fix filter installation
problem.

Advertising
This manual is related to the following products: