4 testing flow switch – Jacuzzi j315 User Manual

Page 26

Advertising
background image

26

2.

3.

4.

Plug in a new control panel. If the problem is corrected, replace the control panel. If the problem
persists, proceed to step 3.
Check the voltage at the transformer secondary. See section A15, page 57, for transformer testing
instructions. If the voltage is bad, replace the transformer. If the voltage is good, proceed to step 4.
Check the circuit board transformer connections. If the connections are loose or oxidized, repair the
connections and retest the system. If the problem persists, replace the circuit board.

7.4 Testing Flow Switch

1.

2.

3.

Verify the fl ow switch directional arrow is pointing in the direction of fl ow towards the heater return
fi tting outlet. If the fl ow switch orientation is incorrect, loosen or tighten the switch no more than 1/2
turn, being careful not to bottom out the switch in the fi tting. The switch’s fl ow arrow must be parallel
to the tee fi tting as shown (fi g. A). Test the system operation. If the condition persists, proceed to
step 2.
Remove the switch from the fi tting making note of the number of turns (revolutions) it takes to do so.
Visually inspect the switch for debris interference or damage. If debris is present, remove the debris,
then reinstall the switch with the same number of turns as originally installed. Test the sytem. If the
switch is damaged, replace the switch and retest the system. If the condition persists, proceed to
step 3.
Test the switch operation with an ohmmeter (set to 1000-2000k range) for continuity across the
switch terminals. Measure resistance across the switch terminals for infi nite resistance with the
magnet arm not touching the switch body (fi g. B), and for continuity (Ø ohms) with the magnet arm
touching the switch body (fi g. B). If the fl ow switch tests OK, check the wiring harness. If the wiring
harness tests OK, replace the circuit board.

fig. A

fig. B

Incorrect

Orientation

Correct

Orientation

FLOW

Arrows

aligned

FLOW

Arrows

not

aligned

Open

Continuity 0 ‰

(Pump ON)

Closed

Infinite ‰

(Pump OFF)